Sample data — Naples Shores is not a real property

Resort Pest Control

Pest Activity Report

Your pest control program treats the outside of all 7 buildings on the property every month. Our technician applies a perimeter treatment around the foundation, doors, windows and other entry points to keep ants, roaches, spiders and other crawling insects from getting inside. On Nov 11, 2026, the perimeter was treated with Termidor SC Termiticide/Insecticide.

Your rodent control program uses 28 rodent bait stations placed around the property. On every visit our technician opens each station, checks how much bait has been eaten, adds fresh bait as needed and records the reading, so we can see where rodents are active and how that changes over time.

On Nov 11, 2026, all 28 stations were inspected and re-baited. 2 stations showed elevated activity (moderate or heavy feeding), down from 3 on the previous visit.

Association
Naples Shores Condominium Association
Units
84
Managed by
Manager: Sample Management Co.
Latest visit
Nov 11, 2026
Technician
Sam Tech · Licence FL-0000001
Visits shown
7 published
Program
Monthly Exterior + Rodent Control28 stations · 7 buildings
Period shown
Jun 11 – Nov 117 visits
Addresses
Building NumbersShown as numbered on site
Corrective actions
1 openOldest 30 days

On Nov 11, all 28 stations were inspected and baited; 2 stations showed elevated activity across 2 buildings

On Nov 11, 2026, Sam Tech inspected all 28 stations and re-baited each one. 2 stations showed elevated activity across 2 buildings, down from 3 on the previous visit. 1 corrective action is open.

Stations baited on property
28 / 28
Every station inspected and re-baited
Elevated activity
2 / 28
▼ 1 since Oct 12
Buildings with elevated activity
2 / 7
At least one station moderate or heavy
Graded heavy
0
Highest consumption grade
Open corrective actions
1
Oldest 30 days

Termite activity at 3 stations in 2 buildings

Live termites at 1 station. All new since the last inspection. Select a station to see it on the termite map.

  • Building 300
  • Building 500

Site Plan – Map

Each station is mapped where it sits on your property, numbered as it is on site. The colour behind a station shows what the technician found on the visit you have selected; the legend beside the map explains the feeding levels and station condition. A green band along a wall marks a perimeter treatment applied on that visit.

100 — 0 of 4 stations with elevated activity200 — 0 of 4 stations with elevated activity300 — 0 of 4 stations with elevated activity400 — 0 of 4 stations with elevated activity500 — 0 of 4 stations with elevated activity600 — 1 of 4 stations with elevated activity700 — 1 of 4 stations with elevated activityNaples Shores Dr100200300400500600700Termite damage: Termite damage found along the base of the east wall at building 300 — mud tubes and soft, hollow-sounding trim. Recommend an interior inspection of the ground-floor units.Termite damage: Damaged fascia and wood trim at the north corner of building 500, with evidence of drywood termites. Photographed for the association's maintenance list.01100-01 — No feed02100-02 — Light03100-03 — No feed04100-04 — No feed01200-01 — No feed02200-02 — No feed03200-03 — No feed04200-04 — Light01300-01 — No feed02300-02 — Light03300-03 — No feed04300-04 — No feed01400-01 — No feed02400-02 — No feed03400-03 — No feed04400-04 — No feed01500-01 — No feed02500-02 — No feed03500-03 — Light04500-04 — No feed01600-01 — Moderate02600-02 — No feed03600-03 — Light04600-04 — No feed01700-01 — No feed02700-02 — Light03700-03 — Moderate04700-04 — No feedT01100-T01 — No activity · Inspected onlyT02100-T02 — No activity · Inspected onlyT01200-T01 — No activity · Inspected onlyT02200-T02 — No activity · Inspected onlyT01300-T01 — Live termites · Switched to TrelonaT02300-T02 — Evidence of activity · Switched to TrelonaT01400-T01 — No activity · Inspected onlyT01500-T01 — No activity · Inspected onlyT02500-T02 — Evidence of activity · Cartridge replacedT01600-T01 — No activity · Inspected onlyT02600-T02 — No activity · Inspected onlyT01700-T01 — No activity · Inspected only

Feeding

  • None
  • Light
  • Moderate
  • Heavy
  • Installed / first fill
  • Expired bait replaced

Condition

  • Damaged
  • No access
  • Moved this visit

Station type

  • Protecta LP
  • Termite station
  • Live termites found
  • Evidence of termite activity

Treatments

  • Perimeter spray band

Highlighted

  • Termite damage

Marks

  • Call-back 90 days

Select a station for its latest reading.

Nov 11, 2026

Property summary

Select a building on the map or in the table below to see its individual stations.

Building summary

Select any row to highlight that building on the map. The trend column shows the building’s highest station reading at each published visit. Termite stations are counted and reported in their own columns.

BuildingRodent stationsElevatedTrendRodent statusTermite stationsTermite status
1004—Light consumption2Clear
2004—Light consumption2Clear
3004—Light consumption2Live termites at 1 station
4004—Clear1Clear
5004—Light consumption2Activity at 1 station
60041Moderate at 1 station2Clear
70041Moderate at 1 station1Clear
Total28212

Materials applied

Reported problems

See something between visits — activity, a damaged station, anything else? Report it here and the office will follow up. Everything reported against this property is listed below; only the office can mark one resolved.

Prefer to call? To report a problem call (239) 555-0199.

Open & scheduled (0)

Nothing outstanding.

Conducive conditions

Bait suppresses a population; these are the conditions feeding and sheltering it. Items stay on this list until they are closed.

Dumpster enclosure gate by building 700 would not latch

The gate stood open overnight and the lids were left up, putting steady food and harborage at the north-east end of the property. Consumption at buildings 600 and 700 would not come down until it was closed at night; the association repaired the latch after the call-back and the activity fell away.

ClosedClosed Sep 21, 2026Owner: Association — grounds

Dense hedge against the north wall of building 600

Vegetation is touching the wall and hides the station at 600-03. Trimming it back 12 inches keeps the station reachable and removes a pathway to the roofline.

MonitorOpened Oct 12, 2026 · 30 daysOwner: Association — grounds